AMF 3.4
Automatic Mains Failure Units - AMF Series

Efficient and versatile control for all Gen-Set applications.

AMF 3.1 offers versatile control functions for single or multiple Generator/Mains applications.

AMF3.4 is a full Automatic Mains Failure unit intended to be used for Mains and Gen-Set control, where high process power is required. The controller can be used with single or three phase mains and generator systems. 3 phase mains and 3 phase generator voltages are measured in true RMS and also 3 phase generator load current is measured. Phase sequence and Reverse Power Protection is provided for the Generator. User can program any of the auxiliary i/o ports for custom applications. The m... »

AMF3.4 is a full Automatic Mains Failure unit intended to be used for Mains and Gen-Set control, where high process power is required. The controller can be used with single or three phase mains and generator systems.

3 phase mains and 3 phase generator voltages are measured in true RMS and also 3 phase generator load current is measured. Phase sequence and Reverse Power Protection is provided for the Generator.

User can program any of the auxiliary i/o ports for custom applications. The menu offers extensive control for each i/o and all the parameters can be configured via PC, using the ENKO PRO-Link configuration program. All the parameters can also be configured from the front panel controls. SMS messages can be sent, using optional GSM interface module. The unit can be programmed from remote distance.

Many of the control variables can be displayed as required on the front panel. There are 3 analog sensor inputs available and characteristics can be adjusted from the menu to fit any type of sensor. There are altogether 13 i/o ports available, among which many can be configured by the user.

Load power is also measured and can be used with dedicated functions in the menu. Decisions can be made depending on active and/or reactive power of the load. Total accumulated active/reactive power is also measured and recorded.

The real-time clock allows weekly and/or monthly generator control programs to be made, which can manage periodic test run and /or disabling the generator at certain hours or on specific days.

Magnetic pick-up input is available for reliable and accurate measurement and control of engine speed.

«

↑ Top KEY FEATURES
  • PC Interface for monitoring and   system programming, SCADA control
  • Real-time clock and time stamped alarm logging
  • Phase sequence detection and reverse power protection
  • Measurement of KW, KVA, KVAr, KWh and Power Factor
  • Magnetic Pick-up input for RPM measurement
  • Independent control of MCB and GCB from front panel
  • Phase sequence and reverse power protection for the Generator
  • Full digital calibration of all analog measuring inputs
  • 3 phase Mains voltage and 3 phase Generator voltage and current measurement
  • Daily or weekly control patterns for the Generator
  • Engine working hour meter and service timer
  • Independent control of MCB and GCB from front panel
↑ Top KEY BENEFITS
  • Automatic or Manual transfer of the Load between the Mains and the Generator
  • Easily receive information regarfing the status of the Generator and view/edit parameters by sending and receiving SMS messages over a mobile phone
  • Option to configure paramters using the front panel or via ENKO Pro-Link SCADA software
  • Dedicated functions for specific applications like Telecom
  • Program weekly work schedules to test or simply run the Generator
  • Internal relay outputs eliminate the need for external relay use
  • The time and date stamped alarm and event logs allow easier and faster troubleshooting and maintenance
  • 3 LED displays and 20 dedicated alarm indicator LED's provide a comprehensive overview of the entire system
  • Total of 18 I/O ports are provided which 13 of them are user configurable

 

DC Supply (Power Supply)
 

  • DC Supply Voltage :
    9 - 35 Vdc
     
  • Maximum Operating Current :
    For 12V Systems    mA
    For 24V Systems    mA
     
  • Stand-by Operating Current :
    For 12V Systems     mA
    For 24V Systems     mA
     
  • Cranking Dropouts :
    Able to withstand dopouts during cranking
     

 

Instrumentation

 

  • Digital Display Type :
    3 Displays with 3 Digit 7 Segment LED's
     
  • Information Shown on Digital Display :
    Mains Voltage and Frequency (Phase-Phase and Phase-Neutral)
    Generator Voltage and Frequency (Phase-Phase and Phase-Neutral)
    Current, KW, KVA, KVAr, KWh and Power Factor
    RPM, Battery Voltage, Charge Alternator Voltage
    Oil Pressure, Coolant Temperature and Fuel Level
    Engine Running Hours
     
  • Alarm & Event Log :
    Time Stamped Last 15 Alarms are Logged
     
  • LED Indicators :
    Mimic Diagram
    20 Failure and Mode LED Indicators
     

Generator and Mains Voltage / Frequency Measurement
 

  • Measurement Type and Source :
    True RMS, 3 Mains and 3 Generator Voltage Inputs
     
  • Phase-Neutral Voltage Measurement Range :
                   Vac
     
  • Phase-Phase Voltage Measurement Range :
    20 - 500 Vac
     
  • Voltage Measurement Accuracy :
    +/- 2% of the Scale
     
  • Voltaj Measurement Resolution:
    1.0 V
     
  • Frequency Measurement Range:
    1-99Hz
     
  • Frequency Measurement Accuracy :
    +/- 0.1Hz
     
  • Frequency Measurement Resolution :
    0.1 Hz

 

Current Measurement

 

  • Measurement Type : 
    3 Phase True RMS
     
  • Current Transformer Seconder Ratio :
    The Primer and Seconder Ratios are Parametric
     
  • Measurement Accuracy :
    +/- 1%
     
  • Measurement Resolution :
    1.0 A
     

Digital Inputs
 

  • Digital Inputs  :
    8 Digital Inputs
     
  • Configurable Inputs :
    8 Configurable Inputs
     
  • Operation Type :
    The Desired Polarite can be Selected Depending on the Common Terminal
    The Common 1 is for Aux. Input 1, 2, 3 and 4
    The Common 8 is for Aux. Input 5, 6, 7 and 8
     

Analog Inputs

 

  • Analog Oil Pressure Measurement Type :
    Resistive
     
  • Analog Oil Pressure Measurement Accuracy :
    +/- 1%
     
  • Analog Oil Pressure Measurement Resolution :
    0.1 Bar
     
  • Analog Coolant Temperature Measurement Type :
    Resistive
     
  • Analog Coolant Temperature Measurement Accuracy :
    +/- 1%
     
  • Analog Coolant Temperature Measurement Resolution :
    0.1 ºC
     
  • Analog Fuel Level Measurement Type :
    Resistive

     
  • Analog Fuel Level Measurement Accuracy :
    +/- 1%

     
  • Analog Fuel Level Measurement Resolution :
    0.1%
Charge Failure Input

 

  • Voltaj Range :
    0 - 35 V
     
  • Excitation Current :
    For 12V Systems 120mA
    For 24V Systems 200mA
     
  • Measurement Accuracy : 
    +/- 1%
     
  • Measurement Resolution :
    0.1V
     

Magnetic Pick-up Input (MPU, RPM)

 

  • Measurement Accuracy :
    +/- 5 RPM
     
  • Measurement Resolution :
    1 RPM
     

Outputs
 

  • Mains and Generator Contactors :
    2 Outputs 10A 250Vac Relay
     
  • Crank and Fuel :
    2 Outputs 16A 250Vac Relay
     
  • Configurable Aux. Outputs :
    5 Outputs 6A 250Vac Relay
     

Communication

 

  • Communication Ports :
    2 Port for TTL Communication
     
  • GSM/GPRS Support :
    Yes (Requires External Modem)
     
  • PC Connectivity : 
    Yes (Requires External Cable)
     
  • ModBUS RTU Support :
    Units Such as PC, PLC and Other Smart Units are Supported Through ModBUS RTU with Accessories.
     
  • Pro-link PC SCADA Support :
    Yes
     

 

Real-time Clock
 

  • Real-time Clock :
    Yes

     
  • Internal Battery Support :
    Yes
     

Environmental Conditions

 

  • Operating Temperature and Humidity Range :
    -35ºC to +70ºC
    20%rH to 99%rH, Non-condensing
     
  • Storage Temperature and Humidity Range :

     
  • ESD Protection :

     
  • EMC Conformance :

     
  • EMI Conformance :

     
  • Vibration :

     
  • Protection Class :
    IP 52 Front Panel Protection

 

Mechanical Specifications

 

  • Dimensions 
    180 mm x 130 mm x 55 mm
     
  • Panel Cut-out :
    164 mm x 116 mm
     
  • Weight : 
    650 gr (Average)
     
  • Mounting Type :
    Panel Mount with Metal Screw Fixings
    Maximum Panel Thickness 3mm
     
There is no software added yet.
  • What are the requirements for configuring the AMF/MSU series controllers via ENKO PC Configuration Suite?

    In order to connect an AMF/MSU controller to the PC, a TTL/USB convertor cable which can be ordered from ENKO is required. Besides the convertor cable the Configuration Suite will require Microsoft .Net Framework 4.0 or better to be installed first. This is a licence free software and can easily be installed from Microsoft.com website or can be installed from the ENKO PC Configuration Suite (Just click yes when prompted during installation).

    The ENKO PC Configuration Suite can be downloaded from our website. Just visit the Software tab on the related product page.

    Models currently supported by the PC Configuration Suite are AMF 3.1, AMF 3.2, AMF 3.4, AMF 3.4L, AMF 5.1, AMF 5.2, MSU 3.1, MSU 3.4L, MSU 5.1 and MSU 5.2.

  • The MCB and GCB buttons on the panel are not functioning. Why?

    The MCB and GCB control is provided on the front panel. These buttons are designed in two different ways. In the AMF 3.4L, AMF 5.1, AMF 5.2, MSU 3.4L, MSU 5.1 and MSU 5.2 models, there are dedicated contactor open and contactor close buttons for the MCB and/or GCB. On the other hand the AMF 3.1, AMF 3.2, AMF 3.4, AMF 4.2, AMF 5.1, MSU 3.1, MSU 3.2, MSU 3.4, MSU 4.2 and MSU 5.1 models these buttons are designed as toggle buttons. 

    The MCB and GCB control buttons will NOT function in AUTO mode. This mode is where the AMF/MSU panel has the control of the contactors and therefore the MCB/GCB buttons are disabled. In order to take control of the MCB and GCB contactors the user must take the AMF/MSU panel into MAN or TEST mode. The contactor buttons will function only in these modes. 

    Another reason why the buttons may not be functioning is the connection mistakes. Please check and make sure the contactors have been connected to the corresponding terminals on the AMF/MSU panel. In order to obtain the connection diagram, please check the Documents tab in the related product page or check the User Manual.