AMF 4.0
Automatic Mains Failure Units - AMF Series

Friendly user interface with analog bar graph displays...

AMF4.0 controller includes two analog bar-graph displays to indicate direct readings from engine temperature and oil pressure gauges. AMF4.0 offers flexible control of load power, fed from mains and generator bus-bars. 

AMF4.0 Automatic Mains Failure (AMF) control module from ENKO offers flexible management of Load and Diesel Generator functions. The MCB and GCB relays can be controlled efficiently, allowing minimum load break, with single Mains/Gen-Set applications.  The controller offers 5 digital displays for monitoring system values. All voltages and currents are measured as True RMS values, with better than 1% full scale accuracy.  All three phase voltages of mains and generator side are me... »

AMF4.0 Automatic Mains Failure (AMF) control module from ENKO offers flexible management of Load and Diesel Generator functions. The MCB and GCB relays can be controlled efficiently, allowing minimum load break, with single Mains/Gen-Set applications. 

The controller offers 5 digital displays for monitoring system values. All voltages and currents are measured as True RMS values, with better than 1% full scale accuracy. 

All three phase voltages of mains and generator side are measured as well as the load phase currents. This allows optimum control of load supply for safe operation. The illuminated mimic diagram allows easy monitoring and function controls on the front panel. 

All system parameters can be configured through an extensive menu. All the I/O ports can be configured and set to match the required application characteristics and all measuring analog inputs can be calibrated, using the system menu. Preset temperature and pressure gauge characteristics can also be selected direct from the menu. 

The controller also includes a “Remote Start” input so that it can be interfaced with other control systems. Remote start characteristics can also be set through the system menu. 

«

↑ Top KEY FEATURES
↑ Top KEY BENEFITS

 

DC Supply (Power Supply)
 

  • DC Supply Voltage :
    9 - 35 Vdc
     
  • Maximum Operating Current :
    For 12V Systems    mA
    For 24V Systems    mA
     
  • Stand-by Operating Current :
    For 12V Systems     mA
    For 24V Systems     mA
     
  • Cranking Dropouts :
    Able to withstand dopouts during cranking
     

 

Instrumentation

 

  • Digital Display Type :
    5 Displays with 3 x 7 Segment LED's
    2 Analog Bar-Graph Displays for Analog Inputs 

     
  • Information Shown on Digital Display :
    Mains Voltage and Frequency (Phase-Phase and Phase-Neutral)
    Generator Voltage and Frequency (Phase-Phase and Phase-Neutral)
    Current, RPM, Battery Voltage
    Coolant Temperature, Oil Pressure
    Engine Running Hours

     
  • Alarm & Event Log :
    Last 10 Alarms are Logged
     
  • LED Indicators :
    Mimic Diagram
    8 Failure and Mode LED Indicators
     

Generator and Mains Voltage / Frequency Measurement
 

  • Measurement Type and Source :
    True RMS, 3 Mains and 3 Generator Voltage Inputs
     
  • Phase-Neutral Voltage Measurement Range :
                   Vac
     
  • Phase-Phase Voltage Measurement Range :
    20 - 500 Vac
     
  • Voltage Measurement Accuracy :
    +/- 2% of the Scale
     
  • Voltaj Measurement Resolution:
    1.0 V
     
  • Frequency Measurement Range:
    1-99Hz
     
  • Frequency Measurement Accuracy :
    +/- 0.1Hz
     
  • Frequency Measurement Resolution :
    0.1 Hz

 

Current Measurement

 

  • Measurement Type : 
    3 Phase True RMS
     
  • Current Transformer Seconder Ratio :
    The Primer and Seconder Ratios are Parametric
     
  • Measurement Accuracy :
    +/- 1%
     
  • Measurement Resolution :
    1.0 A
     

Digital Inputs
 

  • Digital Inputs  :
    4 Digital Inputs
     
  • Configurable Inputs :
    4 Configurable Inputs
     
  • Operation Type :
    The Inputs are Activated via Negative Battery Terminal
     

Analog Inputs

 

  • Analog Oil Pressure Measurement Type :
    Resistive
     
  • Analog Oil Pressure Measurement Accuracy :
    +/- 1%
     
  • Analog Oil Pressure Measurement Resolution :
    0.1 Bar
     
  • Analog Coolant Temperature Measurement Type :
    Resistive
     
  • Analog Coolant Temperature Measurement Accuracy :
    +/- 1%
     
  • Analog Coolant Temperature Measurement Resolution :
    0.1 ºC
     
  • Analog Fuel Level Measurement Not Supported in this Model
Charge Failure Input

 

  • Voltaj Range :
    0 - 35 V
     
  • Excitation Current :
    For 12V Systems 120mA
    For 24V Systems 200mA
     
  • Measurement Accuracy : 
    Not Supported in this Model
     
  • Measurement Resolution :
    Not Supported in this Model
     

Magnetic Pick-up Input (MPU, RPM)

 

  • Not Supported in this Model

     

Outputs
 

  • Generator Contactor :
    1 Output 10A 250Vac Relay
     
  • Crank and Fuel :
    2 Outputs 6A 250Vac Relay
     
  • Configurable Aux. Outputs :
    2 Outputs 6A 250Vac Relay
     

Communication

 

  • Not Supported in this Model

 

Real-time Clock
 

  • Not Supported in this Model

     

Environmental Conditions

 

  • Operating Temperature and Humidity Range :
    -35ºC to +70ºC
    20%rH to 99%rH, Non-condensing
     
  • Storage Temperature and Humidity Range :

     
  • ESD Protection :

     
  • EMC Conformance :

     
  • EMI Conformance :

     
  • Vibration :

     
  • Protection Class :
    IP 52 Front Panel Protection

 

Mechanical Specifications

 

  • Dimensions 
    192 mm x 144 mm x 62 mm
     
  • Panel Cut-out :
    185 mm x 138 mm
     
  • Weight : 
    770 gr (Average)
     
  • Mounting Type :
    Panel Mount with Metal Screw Fixings
    Maximum Panel Thickness 3mm
     